_icone_montair_tecnologie_aircooled_dx_dual_fluid.png

_montair_tech_ec_inverter_plug_fan.png

TOP 1025÷4118

AIRCOOLED DIRECT EXPANSION DUAL FLUID UNITS WITH SCROLL COMPRESSORS AND EC INVERTER PLUG-FANS

_montair_DX_2015.png _montair_Scroll_2015.png _montair_EC_plug_fan_inverter_2015.png _montair_EC_plug_fan_inverter_HIGH_ESP2015.png _montair_icon_refrigerant_R410A_14.png

Dual Fluid unit with direct expansion, air-condensation and double circuit: one with direct expansion and air-condensing, and one with chilled water.
The two circuits are separate and with non-simultaneous start-up, for internal back-up.
The TOP range is equipped with EC Inverter Plug-Fans; High Head fans are available as accessories.
The EC Inverter Plug-Fans allow fuel consumption at partial loads to be reduced by up to 61% compared to radial fans, modulating the power consumption according to the required thermal load.
The TOP range is available in two air delivery configurations: TOPT with upflow and TOPB with downflow.
Unit supervision is developed by means of Modbus RTU protocol over RS485
serial interface as standard configuration. Other communication protocols and
interfaces are available as option.
The units are suitable for operation at a high outdoor air temperature (up to 52 C) with the correct combination with the XT remote condensers.

Versions

  • TOPT/C - Top air discharge and frontal intake
  • TOPT/U - Top air discharge and frontal intake
  • TOPT/E - Top air discharge and frontal intake
  • TOPT/D - Top air discharge and frontal intake
  • TOPB/C - Bottom air discharge and upper intake
  • TOPB/U - Bottom air discharge and upper intake
  • TOPB/E - Bottom air discharge and upper intake
  • TOPB/D - Bottom air discharge and upper intake

Power range

  • 26.0-118 kW
  • 7.3-34.0 Ton

Factory fitted accessories

  • AP High ESP fans
  • SL Unit silencement
  • TE Electronic expansion valve
  • AR Air renewal inlet with filter
  • AT Constant air flow regulation control
  • AT/P Constant available static pressure regulation control
  • PF Differential pressure switch filters control
  • ES Electrical heater with step regulation
  • WS2 Hot water coil with 3-Way valve
  • PG Hot gas post-heating coil (with valve)
  • UMI Electrodes steam humidifier
  • SA Water alarm sensor
  • IST Modbus TCP/IP protocol, Ethernet port
  • ISB BACnet MSTP protocol, RS485 serial interface
  • ISBT BACnet IP protocol, Ethernet port
  • ISS SNMP protocol, Ethernet port
  • LT Unit ready for operation with KLT
  • RE Adjustable minimum/maximum voltage and phase control relay

Loose accessories

  • MP Condensate drain pump
  • MP/U Condensate and humidifier drain pump
  • SB Fire sensor
  • SC Smoke sensor
  • CR Remote control panel
  • ZP Adjustable baseframe with shock absorbers (mod. B only)
  • ZA Adjustable baseframe with shock absorbers and deflector (mod. B only)
  • DL Bottom plenum for side connections (mod. T only)
  • BA Top vertical intake plenum with F7 efficiency filter (mod. B only)
  • BD Top frontal discharge plenum with grid (mod. T only)
  • DM Bottom frontal discharge plenum with grid (mod. B only)
  • BV Top discharge/intake plenum with damper
1025104110502066208041044118
Direct expansion circuit performancesTotal cooling capacity (1)kW25,741,550,366,580,0104118
Sensible cooling capacity (1)kW21,938,842,558,375,095,1100
SHR (1)%85%93%84%88%94%91%85%
Total absorbed power (1)kW7,011,414,017,822,728,732,5
EER (1)3,673,643,593,733,533,633,63
Chilled water circuit performancesTotal cooling capacity (2)kW24,149,249,267,692,1118118
Sensible cooling capacity (2)kW20,942,542,560,381,8102102
SHR (2)%87%86%86%89%89%86%86%
Water flow (2)l/s1,22,42,43,24,45,75,7
Total pressure drops (2)kPa33454533474444
Refrigerant circuitRefrigerant circuits1112222
Compressors1112244
Fan sectionFans1112233
Air flow (3)m³/h5200100001000014200192002400024000
Max. available static pressure - STD fansPa100230230360240320320
Max. available static pressure - High ESP fansPa390370370530380470470
FiltersTipoM5M5M5M5M5M5M5
Electrical characteristicsPower supplyV/Ph/Hz400/3+N/50400/3+N/50400/3+N/50400/3+N/50400/3+N/50400/3+N/50400/3+N/50
Sound pressureTOPT - Top Air Discharge version (4)dB(A)61636463666666
TOPB - Bottom Air Discharge version (4)dB(A)56585957606060
ACCESSORIES & ADDITIONAL SECTIONSACCESSORIES & ADDITIONAL SECTIONS       
Electrical heatingSteps3333333
Electrical powerkW7,513,513,516,522,527,027,0
Hot water coilHeating capacity (5)kW5,213,013,017,724,531,631,6
Water flow (5)l/s0,250,620,620,851,171,511,51
Total pressure drops (5)kPa29363635434141
Hot gas coilHeating capacity (6)kW5,910,510,514,319,825,625,6
Electrodes steam humidifierNominal steam productionkg/h4888151515
Nominal powerkW3,06,06,06,011,311,311,3
WeightsTransport weight TOPT - Top Air Dischargekg32452553767683910501050
Transport weight TOPB - Bottom Air Dischargekg34154255470586810851085
Operating weight TOPT - Top Air Dischargekg31350551765481110171017
Operating weight TOPB - Bottom Air Dischargekg33052253468384010521052

Dimensions

1025104110502066208041044118
DimensionsLmm875135013501750222526252625
Wmm675890890890890890890
Hmm1980198019801980198019801980

Notes

  • 1 Ambient air temperature 24°C - R.H. 50%, condensing temperature 45°C.
  • 2 Ambient air temperature 24°C - R.H. 50%, water temperature 7°C / 12°C.
  • 3 Air flow calculated with Available Static Pressure of 20 Pa.
  • 4 Sound pressure level calculated in free field conditions at 1,5 m height and 2 m distance. According to ISO 3744.
  • 5 Ambient air temperature 20°C, water temperature 45°C / 40°C.
  • 6 Temperatura aria ambiente 20°C.