_icone_montair_tecnologie_aircooled_dx_dual_fluid.png

montair tech_inverter_compressor_2025.png

montair tech_ec_inverter_plug_fan_2025.png

TIP/SZ 1024÷3114

AIR COOLED DIRECT EXPANSION DUAL FLUID UNITS WITH INVERTER SCROLL COMPRESSORS AND EC INVERTER PLUG-FANS

_icona_montair_DF.png _icona_montair_scroll_inverter.png _icona_montair_EC-Inverter-Plug-fan.png _icona_montair_EC-Inverter-Plug-fan_HESP.png _icona_montair_XT.png _icona_clint_refrigerant_R410A_2024.png _icona_montair_60-Hz.png

High efficiency air cooled direct expansion Dual Fluid units with double circuit: one air cooled direct expansion circuit and one chilled water circuit. The circuits are separated, with non-simultaneous start-up, for back-up operation. The Inverter Scroll compressor and the EC Inverter Plug-Fans vary their delivered power and absorbed power depending on the real requested thermal load. Up to 88% difference between minimum and maximum absorbed power is reachable.
The TIP range is equipped with EC Inverter Plug-Fans; High Head fans are available as accessories.
The range features electronic expansion valve already included.
The TIP range is available in two air delivery configurations: TIPT with upflow and TIPB with downflow.
Unit supervision is developed by means of Modbus RTU protocol over RS485
serial interface as standard configuration. Other communication protocols and
interfaces are available as option.
The units are suitable for operation at a high outdoor air temperature (up to 52 C) with the correct combination with the XT remote condensers.

Versions

  • TIPT/SZ - Top air discharge and frontal intake
  • TIPB/SZ - Bottom air discharge and upper intake

Power range

  • 24.0-116 kW

Factory fitted accessories

  • AP High ESP fans
  • SL Unit silencement
  • CM Scheduler
  • EC EC Inverter fans
  • TE Electronic expansion valve
  • AR Air renewal inlet with filter
  • AT Constant air flow regulation control
  • AT/P Constant available static pressure regulation control
  • PA Differential pressure switch fans control
  • PF Differential pressure switch filters control
  • ES Electrical heater with step regulation
  • WS2 Hot water coil with 3-Way valve
  • PG Hot gas post-heating coil (with valve)
  • UMI Electrodes steam humidifier
  • WM Web Monitoring - Wireless remote monitoring (GPRS/EDGE/4G/TCP-IP)
  • SA Water alarm sensor
  • IS Modbus RTU protocol, RS485 serial interface
  • IST Modbus TCP/IP protocol, Ethernet port
  • ISB BACnet MSTP protocol, RS485 serial interface
  • ISBT BACnet IP protocol, Ethernet port
  • ISB1 BACnet MSTP protocol, RS485 serial interface, BTL certified.
  • ISBT1 BACnet IP protocol, Ethernet port, BTL certified.
  • ISS SNMP protocol, Ethernet port
  • RE Adjustable minimum/maximum voltage and phase control relay

Loose accessories

  • MP Condensate drain pump
  • MP/U Condensate and humidifier drain pump
  • SB Fire sensor
  • SC Smoke sensor
  • CR Remote control panel
  • ZP Adjustable baseframe with shock absorbers (mod. B only)
  • ZA Adjustable baseframe with shock absorbers and deflector (mod. B only)
  • DL Bottom plenum for side connections (mod. T only)
  • BA Top vertical intake plenum with F7 efficiency filter (mod. B only)
  • BD Top frontal discharge plenum with grid (mod. T only)
  • DM Bottom frontal discharge plenum with grid (mod. B only)
  • BV Top discharge/intake plenum with damper
  • BF Direct Free-Cooling plenum for units with bottom air discharge
  • DF Direct Free-Cooling plenum for units with top air discharge
10241046206020863114
Direct expansion circuit performancesTotal cooling capacity - Max (1)kW24,147,060,589,0116
Total cooling capacity - Min. (1)kW7,916,018,627,136,3
Sensible cooling capacity - Max. (1)kW18,735,949,968,287,9
Sensible cooling capacity - Min. (1)kW7,916,018,627,136,3
SHR - Max. (1)%78%83%77%
SHR - Min. (1)%100%100%100%100%100%
Total absorbed power - Max (1)kW7,915,417,728,236,7
Total absorbed power - Min. (1)kW2,85,24,06,98,8
EER - Max. (1)3,063,053,423,163,16
EER - Min. (1)2,803,074,673,924,14
Chilled water circuit performancesTotal cooling capacity (2)kW16,838,757,379,699,5
Sensible cooling capacity (2)kW14,532,747,564,981,2
SHR (2)%87%85%83%82%82%
Water flow (2)l/s0,801,842,733,804,74
Total pressure drops (2)kPa2537264037
Refrigerant circuitRefrigerant circuits11122
Compressors11123
Fan sectionFans11223
Air flow (3)m³/h520010000142001920024000
Max. available static pressure - STD fansPA280335400370400
Max. available static pressure - High ESP fansPA790475500485500
FiltersTipoG4G4G4G4G4
Electrical characteristicsPower supplyV/Ph/Hz380/3+N/60380/3+N/60380/3+N/60380/3+N/60380/3+N/60
Sound pressureTIPT - Top Air Discharge version (4)dB(A)6668697173
TIPB - Bottom Air Discharge version (4)dB(A)6062636566
ACCESSORIES & ADDITIONAL SECTIONSACCESSORIES & ADDITIONAL SECTIONS
Electrical heatingSteps-3333
Electrical powerkW-13,516,522,527,0
Hot water coilHeating capacity (5)kW-20,828,639,650,8
Water flow (5)l/s-1,011,381,912,45
Total pressure drops (5)kPa-36434341
Hot gas coilHeating capacity (6)kW-14,417,126,334,6
Electrodes steam humidifierNominal steam productionkg/h-881515
Nominal powerkW-6,06,011,311,3

Dimensions

10241046206020863114
DimensionsLmm8751350175022252625
Wmm675890890890890
Hmm19801980198019801980
WeightsTransport weight TIPT - Top Air Dischargekg3115206648381038
Transport weight TIPB - Bottom Air Dischargekg3395567138931103
Operating weight TIPT - Top Air Dischargekg3015026448131008
Operating weight TIPB - Bottom Air Dischargekg3295376938671074

Notes

  • 1 Ambient air temperature 24°C - R.H. 50%, condensing temperature 45°C.
  • 2 Ambient air temperature 24°C - R.H. 50%, water temperature 7°C / 12°C.
  • 3 Air flow calculated with Available Static Pressure of 20 Pa (0,08 in WG).
  • 4 Sound pressure level calculated in free field conditions at 1,5 m height and 2 m distance. According to ISO 3744.
  • 5 Ambient air temperature 24°C, water temperature 45°C/40°C (post-heating operation).
  • 6 Temperatura aria ambiente 24°C.