_icone_montair_tecnologie_chilled_water_dual_coil.png

_montair_tech_ec_inverter_plug_fan.png

DOP 0028÷0093

CHILLED WATER Dual coil UNITS WITH EC INVERTER PLUG-FAN

_montair_CHILLED_H2O_2015.png _montair_DUAL_COIL_2015.png _montair_EC_plug_fan_inverter_2015.png _montair_EC_plug_fan_inverter_HIGH_ESP2015.png _montair_HT_2015.png

Dual Coil units with two independent cooling circuits, both with chilled water. The circuits are connected with two watercooled or aircooled liquid Chillers, with Free-Cooling technology too. The two circuits are separated with nonsimultaneous start-up, for back-up operation.
The DOP range is equipped with EC Inverter Plug-Fans; High Head fans are available as accessories.
The EC Inverter Plug-Fans allow fuel consumption at partial loads to be reduced by up to 61% compared to radial fans, modulating the power consumption according to the required thermal load.
The DOP range is available in two air discharge versions: DOPT with top air discharge and DOPB with bottom air discharge.
Unit supervision is developed by means of Modbus RTU protocol over RS485
serial interface as standard configuration. Other communication protocols and
interfaces are available as option.

Versions

  • DOPT/C - Top air discharge and frontal intake
  • DOPT/U - Top air discharge and frontal intake
  • DOPT/E - Top air discharge and frontal intake
  • DOPT/D - Top air discharge and frontal intake
  • DOPB/C - Bottom air discharge and upper intake
  • DOPB/U - Bottom air discharge and upper intake
  • DOPB/E - Bottom air discharge and upper intake
  • DOPB/D - Bottom air discharge and upper intake

Power range

  • 29,0-93,0 kW
  • 8,1-26,0 Ton

Factory fitted accessories

  • AP High ESP fans
  • HT High water temperature operation 13/18°C
  • DPS Double power supply
  • AR Air renewal inlet with filter
  • AT Constant air flow regulation control
  • AT/P Constant available static pressure regulation control
  • PF Differential pressure switch filters control
  • ES Electrical heater with step regulation
  • WS2 Hot water coil with 3-Way valve
  • UMI Electrodes steam humidifier
  • SA Water alarm sensor
  • IST Modbus TCP/IP protocol, Ethernet port
  • ISB BACnet MSTP protocol, RS485 serial interface
  • ISBT BACnet IP protocol, Ethernet port
  • ISS SNMP protocol, Ethernet port
  • RE Adjustable minimum/maximum voltage and phase control relay

Loose accessories

  • MP Condensate drain pump
  • MP/U Condensate and humidifier drain pump
  • SB Fire sensor
  • SC Smoke sensor
  • CR Remote control panel
  • ZP Adjustable baseframe with shock absorbers (mod. B only)
  • ZA Adjustable baseframe with shock absorbers and deflector (mod. B only)
  • DL Bottom plenum for side connections (mod. T only)
  • BA Top vertical intake plenum with F7 efficiency filter (mod. B only)
  • BD Top frontal discharge plenum with grid (mod. T only)
  • DM Bottom frontal discharge plenum with grid (mod. B only)
  • BV Top discharge/intake plenum with damper