_icone_montair_tecnologie_chilled_water.png

_montair_tech_ec_inverter_plug_fan.png

WOP 0009÷0155

CHILLED WATER UNITS WITH EC INVERTER PLUG-FANS

_montair_CHILLED_H2O_2015.png _montair_EC_plug_fan_inverter_2015.png _montair_EC_plug_fan_inverter_HIGH_ESP2015.png _montair_HT_2015.png

Chilled water units. The liquid Chiller can be watercooled or aircooled, with Free-Cooling technology too. The liquid flow through the unit water coil is managed by a 3-way internal valve.
The WOP range is equipped with EC Inverter Plug-Fans; High Head fans are available as accessories.
The EC Inverter Plug-Fans allow fuel consumption at partial loads to be reduced by up to 61% compared to radial fans, modulating the power consumption according to the required thermal load.
The WOP range is available in two air delivery configurations: WOPT with upflow and WOPB with downflow.
Unit supervision is developed by means of Modbus RTU protocol over RS485
serial interface as standard configuration. Other communication protocols and
interfaces are available as option.
The WOP units can operate with water at a high temperature (13/18°C) thanks to the specific HT accessory: the batteries are optimised for this set point to achieve greater energy efficiency.

Versions

  • WOPT/C - Top air discharge and frontal intake
  • WOPT/U - Top air discharge and frontal intake
  • WOPT/E - Top air discharge and frontal intake
  • WOPT/D - Top air discharge and frontal intake
  • WOPB/C - Bottom air discharge and upper intake
  • WOPB/U - Bottom air discharge and upper intake
  • WOPB/E - Bottom air discharge and upper intake
  • WOPB/D - Bottom air discharge and upper intake

Power range

  • 8,6-155 kW
  • 2,4-44,0 Ton

Factory fitted accessories

  • AP High ESP fans
  • HT High water temperature operation 13/18°C
  • DPS Double power supply
  • AR Air renewal inlet with filter
  • AT Constant air flow regulation control
  • AT/P Constant available static pressure regulation control
  • PF Differential pressure switch filters control
  • ES Electrical heater with step regulation
  • WS2 Hot water coil with 3-Way valve
  • UMI Electrodes steam humidifier
  • SA Water alarm sensor
  • IST Modbus TCP/IP protocol, Ethernet port
  • ISB BACnet MSTP protocol, RS485 serial interface
  • ISBT BACnet IP protocol, Ethernet port
  • ISS SNMP protocol, Ethernet port
  • RE Adjustable minimum/maximum voltage and phase control relay

Loose accessories

  • MP Condensate drain pump
  • MP/U Condensate and humidifier drain pump
  • SB Fire sensor
  • SC Smoke sensor
  • CR Remote control panel
  • ZP Adjustable baseframe with shock absorbers (mod. B only)
  • ZA Adjustable baseframe with shock absorbers and deflector (mod. B only)
  • DL Bottom plenum for side connections (mod. T only)
  • BA Top vertical intake plenum with F7 efficiency filter (mod. B only)
  • BD Top frontal discharge plenum with grid (mod. T only)
  • DM Bottom frontal discharge plenum with grid (mod. B only)
  • BV Top discharge/intake plenum with damper