_icone_montair_tecnologie_watercooled_dx.png

_montair_tech_ec_inverter_plug_fan.png

HOP 1009÷2152

WATERCOOLED DIRECT EXPANSION UNITS WITH SCROLL COMPRESSORS AND EC INVERTER PLUG-FANS

_montair_DX_2015.png _montair_Scroll_2015.png _montair_EC_plug_fan_inverter_2015.png _montair_EC_plug_fan_inverter_HIGH_ESP2015.png _montair_icon_refrigerant_R410A_14.png

Unit with direct expansion and water-condensing.
The air in the room is handled in the evaporator coil where the coolant flows; the condensation heat is disposed of in an internal plate exchanger, in turn connected to a water circuit: well, local water line or closed circuits such as cooling towers and/or Dry-Coolers.
The HOP range is equipped with EC Inverter Plug-Fans; High Head fans are available as accessories.
The EC Inverter Plug-Fans allow fuel consumption at partial loads to be reduced by up to 61% compared to radial fans, modulating the power consumption according to the required thermal load.
The HOP range is available in two air discharge versions: HOPT with top air discharge and HOPB with bottom air discharge.
Unit supervision is developed by means of Modbus RTU protocol over RS485
serial interface as standard configuration. Other communication protocols and
interfaces are available as option.

Versions

  • HOPT/C - Top air discharge and frontal intake
  • HOPT/U - Top air discharge and frontal intake
  • HOPT/E - Top air discharge and frontal intake
  • HOPT/D - Top air discharge and frontal intake
  • HOPB/C - Bottom air discharge and upper intake
  • HOPB/U - Bottom air discharge and upper intake
  • HOPB/E - Bottom air discharge and upper intake
  • HOPB/D - Bottom air discharge and upper intake

Power range

  • 9,6-152 kW
  • 2,7-43,0 Ton

Factory fitted accessories

  • AP High ESP fans
  • PL Plate exchanger for well water with 2-way pressostatic valve
  • PV Pressure valve (for cooling only versions)
  • SL Unit silencement
  • TE Electronic expansion valve
  • AR Air renewal inlet with filter
  • AT Constant air flow regulation control
  • AT/P Constant available static pressure regulation control
  • PF Differential pressure switch filters control
  • ES Electrical heater with step regulation
  • WS2 Hot water coil with 3-Way valve
  • PG Hot gas post-heating coil (with valve)
  • UMI Electrodes steam humidifier
  • SA Water alarm sensor
  • IST Modbus TCP/IP protocol, Ethernet port
  • ISB BACnet MSTP protocol, RS485 serial interface
  • ISBT BACnet IP protocol, Ethernet port
  • ISS SNMP protocol, Ethernet port
  • RE Adjustable minimum/maximum voltage and phase control relay

Loose accessories

  • MP Condensate drain pump
  • MP/U Condensate and humidifier drain pump
  • SB Fire sensor
  • SC Smoke sensor
  • CR Remote control panel
  • ZP Adjustable baseframe with shock absorbers (mod. B only)
  • ZA Adjustable baseframe with shock absorbers and deflector (mod. B only)
  • DL Bottom plenum for side connections (mod. T only)
  • BA Top vertical intake plenum with F7 efficiency filter (mod. B only)
  • BD Top frontal discharge plenum with grid (mod. T only)
  • DM Bottom frontal discharge plenum with grid (mod. B only)
  • BV Top discharge/intake plenum with damper