_icone_montair_tecnologie_aircooled_dx_dual_fluid.png

montair tech_inverter_compressor_2025.png

montair tech_ec_inverter_plug_fan_2025.png

TIP 1026÷3120

AIR COOLED DIRECT EXPANSION DUAL FLUID UNITS WITH INVERTER SCROLL COMPRESSORS AND EC INVERTER PLUG-FANS

_icona_montair_DF.png _icona_montair_scroll_inverter.png _icona_montair_EC-Inverter-Plug-fan.png _icona_montair_EC-Inverter-Plug-fan_HESP.png _icona_montair_XT.png _icona_clint_refrigerant_R410A_2024.png

High efficiency air cooled direct expansion Dual Fluid units with double circuit: one air cooled direct expansion circuit and one chilled water circuit. The circuits are separated, with non-simultaneous start-up, for back-up operation. The Inverter Scroll compressor and the EC Inverter Plug-Fans vary their delivered power and absorbed power depending on the real requested thermal load. Up to 88% difference between minimum and maximum absorbed power is reachable.
The TIP range is equipped with EC Inverter Plug-Fans; High Head fans are available as accessories.
The range features electronic expansion valve already included.
The TIP range is available in two air delivery configurations: TIPT with upflow and TIPB with downflow.
Unit supervision is developed by means of Modbus RTU protocol over RS485
serial interface as standard configuration. Other communication protocols and
interfaces are available as option.
The units are suitable for operation at a high outdoor air temperature (up to 52 C) with the correct combination with the XT remote condensers.

Versions

  • TIPT - Top air discharge and frontal intake
  • TIPB - Bottom air discharge and upper intake

Power range

  • 26,0-122 kW

Factory fitted accessories

  • AP High ESP fans
  • SL Unit silencement
  • AT Constant air flow regulation control
  • AT/P Constant available static pressure regulation control
  • PF Differential pressure switch filters control
  • ES Electrical heater with step regulation
  • WS2 Hot water coil with 3-Way valve
  • PG Hot gas post-heating coil (with valve)
  • UMI Electrodes steam humidifier
  • SA Water alarm sensor
  • IST Modbus TCP/IP protocol, Ethernet port
  • ISB BACnet MSTP protocol, RS485 serial interface
  • ISBT BACnet IP protocol, Ethernet port
  • ISS SNMP protocol, Ethernet port
  • LT Unit ready for operation with KLT
  • RE Adjustable minimum/maximum voltage and phase control relay

Loose accessories

  • MP Condensate drain pump
  • MP/U Condensate and humidifier drain pump
  • SB Fire sensor
  • SC Smoke sensor
  • CR Remote control panel
  • ZP Adjustable baseframe with shock absorbers (mod. B only)
  • ZA Adjustable baseframe with shock absorbers and deflector (mod. B only)
  • DL Bottom plenum for side connections (mod. T only)
  • BA Top vertical intake plenum with F7 efficiency filter (mod. B only)
  • BD Top frontal discharge plenum with grid (mod. T only)
  • DM Bottom frontal discharge plenum with grid (mod. B only)
  • BV Top discharge/intake plenum with damper
  • BF Direct Free-Cooling plenum for units with bottom air discharge
  • DF Direct Free-Cooling plenum for units with top air discharge