XOP 1009÷2140

AIR COOLED DIRECT EXPANSION UNITS WITH SCROLL COMPRESSORS AND EC INVERTER PLUG-FANS

_icona_montair_DX.png _icona_montair_scroll.png _icona_montair_EC-Inverter-Plug-fan.png _icona_montair_EC-Inverter-Plug-fan_HESP.png _icona_montair_XT.png _icona_clint_refrigerant_R410A_2024.png

Air cooled direct expansion units. The XOP range features EC Inverter Plug-Fans; high ESP fans are also available as accessory.
The EC Inverter Plug-Fans allow fuel consumption at partial loads to be reduced by up to 61% compared to centrifugal fans, modulating the power consumption according to the required thermal load.
The XOP range is available in two air delivery configurations: XOPT with upflow and XOPB with downflow.
Unit supervision is developed by means of Modbus RTU protocol over RS485
serial interface as standard configuration. Other communication protocols and
interfaces are available as option.
The units are suitable for operation at a high outdoor air temperature (up to 52 C) with the correct combination with the XT remote condensers.

Versions

  • XOPT - Top air discharge and frontal intake
  • XOPB - Bottom air discharge and upper intake

Power range

  • 9.2-144 kW
  • 2.6-41.0 Ton

Factory fitted accessories

  • AP High ESP fans
  • SL Unit silencement
  • TE Electronic expansion valve
  • AT Constant air flow regulation control
  • AT/P Constant available static pressure regulation control
  • PF Differential pressure switch filters control
  • ES Electrical heater with step regulation
  • WS2 Hot water coil with 3-Way valve
  • PG Hot gas post-heating coil (with valve)
  • UMI Electrodes steam humidifier
  • SA Water alarm sensor
  • IST Modbus TCP/IP protocol, Ethernet port
  • ISB BACnet MSTP protocol, RS485 serial interface
  • ISBT BACnet IP protocol, Ethernet port
  • ISS SNMP protocol, Ethernet port
  • LT Unit ready for operation with KLT
  • RE Adjustable minimum/maximum voltage and phase control relay

Loose accessories

  • MP Condensate drain pump
  • MP/U Condensate and humidifier drain pump
  • SB Fire sensor
  • SC Smoke sensor
  • CR Remote control panel
  • ZP Adjustable baseframe with shock absorbers (mod. B only)
  • ZA Adjustable baseframe with shock absorbers and deflector (mod. B only)
  • DL Bottom plenum for side connections (mod. T only)
  • BA Top vertical intake plenum with F7 efficiency filter (mod. B only)
  • BD Top frontal discharge plenum with grid (mod. T only)
  • DM Bottom frontal discharge plenum with grid (mod. B only)
  • BV Top discharge/intake plenum with damper
  • BF Direct Free-Cooling plenum for units with bottom air discharge
  • DF Direct Free-Cooling plenum for units with top air discharge
1009101110151020102510302035104020482055206510702080209021004110412041302140
PerformancesTotal cooling capacity (1)kW9,211,815,920,524,830,635,942,249,856,567,372,281,293,1104113124135144
Sensible cooling capacity (1)kW7,59,813,116,319,924,131,639,241,047,255,562,966,183,286,8102107111116
SHR (1)%82%83%82%80%81%79%88%93%82%84%83%87%82%89%83%90%86%83%81%
Total absorbed power (1)kW2,403,104,105,306,307,6210,2011,1013,0014,1017,4017,9020,2023,9026,4027,4030,8034,5035,30
EER (1)3,793,783,853,843,924,023,523,803,834,013,874,034,023,903,944,124,033,914,08
Refrigerant circuitRefrigerant circuits1111112122212222222
Compressors1111112122212224442
Fan sectionFans1111111111222223333
Air flow (2)m³/h25003000330039005600560011500115001150011500160001600016000210002100025500255002550025500
Max. available static pressure - STD fansPA545415450385255240220210215200300300300325305350350350350
Max. available static pressure - High ESP fansPA895835750750700695460445445430535515520490470515495495495
FiltersTipoM5M5M5M5M5M5M5M5M5M5M5M5M5M5M5M5M5M5M5
Electrical characteristicsPower supplyV/Ph/Hz230/1/50230/1/50400/3+N/50400/3+N/50400/3+N/50400/3+N/50400/3+N/50400/3+N/50400/3+N/50400/3+N/50400/3+N/50400/3+N/50400/3+N/50400/3+N/50400/3+N/50400/3+N/50400/3+N/50400/3+N/50400/3+N/50
Sound pressureXOPT - Top Air Discharge version (3)dB(A)53565861626265656566646863676866676771
XOPB - Bottom Air Discharge version (3)dB(A)48515356575760606060586258626361616165
ACCESSORIES & ADDITIONAL SECTIONSACCESSORIES & ADDITIONAL SECTIONS
Electrical heatingSteps3333333333333333333
Electrical powerkW4,54,54,54,57,57,513,513,513,513,516,516,516,522,522,527,027,027,027,0
Electrodes steam humidifierNominal steam productionkg/h4444448888888151515151515
Nominal powerkW3,03,03,03,03,03,06,06,06,06,06,06,06,011,311,311,311,311,311,3

Dimensions

1009101110151020102510302035104020482055206510702080209021004110412041302140
DimensionsLmm6756756756758758751350135013501350175017501750222522252625262526252625
Wmm675675675675675675890890890890890890890890890890890890890
Hmm1980198019801980198019801980198019801980198019801980198019801980198019801980
WeightsTransport weight XOPT - Top Air Dischargekg237246249253288305484480499534621641679771798982100810061031
Transport weight XOPB - Bottom Air Dischargekg2552632672703063225024985175516506707088008271017104410421067
Operating weight XOPT - Top Air Dischargekg227236239243277294464460479514599619657743770949975973998
Operating weight XOPB - Bottom Air Dischargekg245253257260295311482478497531628648686772799984101110091034

Notes

  • 1 Ambient air temperature 24°C - R.H. 50%, condensing temperature 45°C.
  • 2 Air flow calculated with Available Static Pressure of 20 Pa (0,08 in WG).
  • 3 Sound pressure level calculated in free field conditions at 1,5 m height and 2 m distance. According to ISO 3744.