WOPR-ER 0015÷0030
HIGH PERFORMING CHILLED WATER IN RACK ENCLOSURE + REDUNDANCY CONDITIONING UNITS



It is also possible to achieve a fully redundant system WOPR-ER by coupling the rack with two chilled water cooling modules. These systems are flexible, easy to be implemented and they are the perfect solution for different applications such as micro data centers, high density servers, EDGE computing, IOT applications, 5G devices. The two modules can operate in a Master/Slave configuration with one unit working and one unit in stand-by with rotation of the stand-by unit on time basis.
These units are equipped with EC Inverter Plug-Fans with backward curved blades and a cooling coil optimised to operate with high inlet water temperature and a large ∆T. Variations in heat load are controlled by the simultaneous action of a 2-way or 3-way modulation valve and automatic fan speed control by means of microprocessor-controlled control logic and an advanced user interface.
Versions
- WOPR-ER - Enclosure type with Redundancy - 1200 mm
Power range
- 21.0-43.0 kW
- 5.9-12.0 Ton
Accessories
Factory fitted accessories
- R6 Rack for Enclosure 600 x 1200 x 42U
- R8 Rack for Enclosure 800 x 1200 x 42U
- MP Condensate drain pump
- DPS Double power supply
- SA Water alarm sensor
- IS Modbus RTU protocol, RS485 serial interface
- IST Modbus TCP/IP protocol, Ethernet port
- ISB BACnet MSTP protocol, RS485 serial interface
- ISBT BACnet IP protocol, Ethernet port
- ISS SNMP protocol, Ethernet port
- MVP 2 way modulating and balancing valve with flow meter, pressure independent
- MQ 3-Way modulating valve
- OW Outlet water temperature sensor
- TCI Hydraulic connections from the top
Loose accessories
- CR Remote control panel
Technical data
0015 | 0020 | 0025 | 0030 | |||
Performances | Total cooling capacity (1) | kW | 20,6 | 28,2 | 34,3 | 42,7 |
Sensible cooling capacity (1) | kW | 20,6 | 28,2 | 34,3 | 42,7 | |
SHR (1) | % | 1 | 1 | 1 | 1 | |
Fans | N° | 3 | 3 | 4 | 6 | |
Air flow | m³/h | 3000 | 4000 | 5400 | 5800 | |
Fan energy consumption | kW | 0,27 | 0,39 | 0,52 | 0,65 | |
Water flow (1) | l/s | 0,82 | 1,12 | 1,37 | 1,70 | |
Pressure drops (1) | kPa | 49,0 | 39,3 | 46,0 | 61,1 | |
Power supply | V/Ph/Hz | 230/1/50 | 230/1/50 | 230/1/50 | 230/1/50 |
Dimensions
0015 | 0020 | 0025 | 0030 | |||
Indoor unit dimensions | L (2) | mm | 300+300+Rack | 300+300+Rack | 300+300+Rack | 300+300+Rack |
W (3) | mm | 1200 | 1200 | 1200 | 1200 | |
H | mm | 2073 (42 U) | 2073 (42 U) | 2073 (42 U) | 2073 (42 U) | |
Weight indoor unit | Weight | kg | 200 | 206 | 211 | 216 |
Weight - Rack 600 | kg | 175 | 175 | 175 | 175 | |
Weight - Rack 800 | kg | 205 | 205 | 205 | 205 |
Notes
- 1 Return air 46°C - 20% rh and 14/20°C water temperature.
Documents
- Product overview (IT) montair_close_control_over_05_2025_ITA_w.pdf
- Product overview (EN) montair_close_control_over_05_2025_ENG_w.pdf
- Product guides (IT) montair_close_control_product_guide_05_2025_ITA_w.pdf
- Product guides (EN) montair_close_control_product_guide_05_2025_ENG_w.pdf
- Commercial leaflets montair_IN-ROW_05_2025_w.pdf
- Technical brochures 06_IN_ROW__IN_RACK_mtb_229_JZFJNl0.pdf