WOPR-E 0015÷0030
HIGH PERFORMING CHILLED WATER IN RACK ENCLOSURE CONDITIONING UNITS
Enclosure solution allows a complete integration of Rack and Cooling system in a common cabinet. The hot air rejected by the servers is addressed to the cooling unit and cold air flows to the servers without risk of mixing. This solution ensures an efficient and accurate control of the air temperature to the IT apparatus independently on the room conditions. The Rack can be 600 or 800 mm wide and is matched with a single Chilled Water cooling module WOPR.
These units are equipped with EC Inverter Plug-Fans with backward curved blades and a cooling coil optimised to operate with high inlet water temperature and a large ∆T. Variations in heat load are controlled by the simultaneous action of a 2-way or 3-way modulation valve and automatic fan speed control by means of microprocessor-controlled control logic and an advanced user interface.
Versions
- WOPR-E - Enclosure type 1200 mm
Power range
- 21.0-43.0 kW
- 5.9-12.0 Ton
Accessories
Factory fitted accessories
- R6 Rack for Enclosure 600 x 1200 x 42U
- R8 Rack for Enclosure 800 x 1200 x 42U
- MP Condensate drain pump
- DPS Double power supply
- SA Water alarm sensor
- IS Modbus RTU protocol, RS485 serial interface
- IST Modbus TCP/IP protocol, Ethernet port
- ISB BACnet MSTP protocol, RS485 serial interface
- ISBT BACnet IP protocol, Ethernet port
- ISS SNMP protocol, Ethernet port
- MVP 2 way modulating and balancing valve with flow meter, pressure independent
- MQ 3-Way modulating valve
- OW Outlet water temperature sensor
- TCI Hydraulic connections from the top
Loose accessories
- CR Remote control panel
Technical data
| 0015 | 0020 | 0025 | 0030 | |||
| Performances | Total cooling capacity (1) | kW | 20,6 | 28,2 | 34,3 | 42,7 |
| Sensible cooling capacity (1) | kW | 20,6 | 28,2 | 34,3 | 42,7 | |
| SHR (1) | % | 1 | 1 | 1 | 1 | |
| Fans | N° | EC Plug-Fans | EC Plug-Fans | EC Plug-Fans | EC Plug-Fans | |
| Air flow | m³/h | 3000 | 4000 | 5400 | 5800 | |
| Fan energy consumption | kW | 0,27 | 0,39 | 0,52 | 0,65 | |
| Water flow (1) | l/s | 0,82 | 1,12 | 1,37 | 1,70 | |
| Pressure drops (1) | kPa | 49,0 | 39,3 | 46,0 | 61,1 | |
| Power supply | V/Ph/Hz | 230/1/50 | 230/1/50 | 230/1/50 | 230/1/50 | |
Dimensions
| 0015 | 0020 | 0025 | 0030 | |||
| Indoor unit dimensions | L (2) | mm | 300+Rack | 300+Rack | 300+Rack | 300+Rack |
| W (3) | mm | 1200 | 1200 | 1200 | 1200 | |
| H | mm | 2073 (42 U) | 2073 (42 U) | 2073 (42 U) | 2073 (42 U) | |
| Weight indoor unit | Weight | kg | 200 | 206 | 211 | 216 |
| Weight - Rack 600 | kg | 175 | 175 | 175 | 175 | |
| Weight - Rack 800 | kg | 205 | 205 | 205 | 205 | |
Notes
- 1 Return air 46°C - 20% rh and 14/20°C water temperature.
Documents
- Product overview (IT) montair_close_control_over_05_2025_ITA_w.pdf
- Product overview (EN) montair_close_control_over_05_2025_ENG_w.pdf
- Product guides (IT) montair_close_control_product_guide_05_2025_ITA_w.pdf
- Product guides (EN) montair_close_control_product_guide_05_2025_ENG_w.pdf
- Commercial leaflets montair_IN-ROW_05_2025_w.pdf
- Technical brochures 06_IN_ROW__IN_RACK_mtb_229_JZFJNl0.pdf