WOPR-E 0015÷0030
HIGH PERFORMING CHILLED WATER AIR CONDITIONING UNITS IN RACK ENCLOSURE




Enclosure solution allows a complete integration of Rack and Cooling system in a common cabinet. The hot air rejected by the servers is addressed to the cooling unit and cold air flows to the servers without risk of mixing. This solution ensures an efficient and accurate control of the air temperature to the IT apparatus independently on the room conditions. The Rack can be 600 or 800 mm wide and is matched with a single Chilled Water cooling module WOPR.
Versions
- WOPR-E/C - Enclosure type 1200 mm
- R6 - Rack for Enclosure 600 x 1200 x 42U
- R8 - Rack for Enclosure 800 x 1200 x 42U
Power range
- 19.0-39.0 kW
- 5.5-11.0 Ton
Accessories
Factory fitted accessories
- MP Condensate drain pump
- DPS Double power supply
- SA Water alarm sensor
- IS Modbus RTU protocol, RS485 serial interface
- IST Modbus TCP/IP protocol, Ethernet port
- ISB BACnet MSTP protocol, RS485 serial interface
- ISBT BACnet IP protocol, Ethernet port
- ISS SNMP protocol, Ethernet port
- MVP 2 way modulating and balancing valve with flow meter, pressure independent
- MQ 3-Way modulating valve
- OW Outlet water temperature sensor
- TCI Hydraulic connections from the top
Loose accessories
- CR Remote control panel
Technical data
0015 | 0020 | 0025 | 0030 | |||
Performances | Total cooling capacity (1) | kW | 19,2 | 25,8 | 31,8 | 39,3 |
Sensible cooling capacity (1) | kW | 19,2 | 25,8 | 31,8 | 39,3 | |
SHR (1) | % | 1 | 1 | 1 | 1 | |
Fans | Tipo | 3 | 3 | 4 | 6 | |
Fans | n° | EC Plug-Fans | EC Plug-Fans | EC Plug-Fans | EC Plug-Fans | |
Air flow | m³/h | 3000 | 4000 | 5400 | 5800 | |
Fan energy consumption | kW | 0,31 | 0,43 | 0,52 | 0,67 | |
Water flow (1) | l/s | 0,75 | 1,03 | 1,27 | 1,56 | |
Pressure drops (1) | kPa | 49,0 | 39,3 | 46,0 | 61,1 | |
Power supply | V/Ph/Hz | 230/1/50 | 230/1/50 | 230/1/50 | 230/1/50 | |
Weight indoor unit | Weight | kg | 200 | 206 | 211 | 216 |
Weight - Rack 600 | kg | 175 | 175 | 175 | 175 | |
Weight - Rack 800 | kg | 205 | 205 | 205 | 205 |
Dimensions
0015 | 0020 | 0025 | 0030 | |||
Indoor unit dimensions | L (2) | mm | 300+Rack | 300+Rack | 300+Rack | 300+Rack |
W (3) | mm | 1200 | 1200 | 1200 | 1200 | |
H | mm | 2073 (42 U) | 2073 (42 U) | 2073 (42 U) | 2073 (42 U) |
Notes
- 1 Return air 46°C - 20% rh and 14/20°C water temperature.
- 2 Rack 600 mm or Rack 800 mm width.
- 3 Nominal dimension (overall dimension 1250mm).
Documents
- Product overview (IT) _montair_close_control_over_2023_ITA_w.pdf
- Product overview (EN) _montair_close_control_over_2023_ENG_w.pdf
- Product overview (ES) _montair_close_control_over_2023_SPA_w.pdf
- Product guides (IT) _montair_close_control_product_guide_2023_ITA_w.pdf
- Product guides (EN) _montair_close_control_product_guide_2023_ENG_w.pdf
- Commercial leaflets 09_IN-ROW__IN_RACK_mtd_229.pdf
- Technical brochures 06_IN_ROW__IN_RACK_mtb_229.pdf