A BROAD RANGE FOR DIFFERENT NEEDS

A BROAD RANGE FOR DIFFERENT NEEDS

MONTAIR offers new ranges, specifically designed on real thermal power loads of server rooms (kW/rack): for traditional, medium-density or latest-generation, high-density Data Centres.

MEDIUM DENSITY

1024-724.png

CLOSE CONTROL UNITS <20 kW/rack

The server room and its cooling system are designed to create hot and cold aisles.

As the thermal power generated by the racks increases, in order to reduce dispersion of the cold air produced by the Close Control units, the server room can be designed according to the logic of contained cold aisles.

By closing the racks with dedicated walls, it prevents hot and cold air from mixing at the top of the aisles, thereby ensuring that all the cold air generated by the Close Control units is directed towards the servers.

This is the simplest solution, with the most reduced investment, and its flexibility makes it possible to re-design the server room quickly if any changes need to be made to the layout.

DIRECT EXPANSION FULL INVERTER CLOSE CONTROL LINE

It includes Air cooled models with Inverter technology applied to compressors and Plug-Fans.

This broad line covers cooling capacities from 17 to 136 kW (from 5 to 39 TON) and includes the ranges:

  • XIP: AIR COOLED DIRECT EXPANSION UNITS WITH FULL INVERTER TECHNOLOGY.
  • TIP: AIR COOLED DIRECT EXPANSION DUAL FLUID UNITS WITH FULL INVERTER TECHNOLOGY.

DIRECT EXPANSION CLOSE CONTROL LINE

It covers cooling capacities from 9 to 152 kW (from 3 to 43 TON) and includes both Air cooled and Water cooled ranges:

  • XOP and XOC: AIR COOLED DIRECT EXPANSION UNITS.
  • TOP and TOC: AIR COOLED DIRECT EXPANSION DUAL FLUID UNITS.
  • HOP and HOC: WATER COOLED DIRECT EXPANSION UNITS.
  • FOP and FOC: WATER COOLED DIRECT EXPANSION FREE-COOLING UNITS.

EC Inverter Plug-Fans or radial fans, depending on the model, provide optimised air flow for the requested thermal load.

CHILLED WATER CLOSE CONTROL LINE

It covers cooling capacities from 9 to 282 kW (from 3 to 80 TON):

  • WOP and WOC: CHILLED WATER UNITS.
  • DOP and DOC: CHILLED WATER DUAL COIL UNITS.
  • WOPU: CHILLED WATER UNDERFLOOR UNITS.
  • DOPU: CHILLED WATER DUAL COIL UNDERFLOOR UNITS.


EC Inverter Plug-Fans or radial fans, depending on the model, provide optimised air flow for the requested thermal load.

HIGH DENSITY

Montair Logica.png

LOGICA SYSTEM >20 kW/rack

The rapid technological progress in the IT industry over recent years has led to the development of increasingly higher performing Servers and Data Centres with thermal loads of increasingly higher density. These Data Centres require high-level and performing cooling systems.

LOGICA SYSTEM: THE FUTURE OF HIGH-DENSITY DATA CENTRES.

It is the latest generation system for high density server rooms, where the thermal load produced by the servers is particularly high. LOGICA goes beyond the concept of hot and cold aisles. In fact it provides localised cooling, focusing directly on hot spots caused by the servers, through a cooling doors system installed directly on the racks.

The energy efficiency is boosted to the maximum and therefore the Data Centre operating costs drop drastically.

LOGICA is a hydronic system based on a patented negative pressure technology named Leak Prevention System: servers are fully protected against any water leaks that might occur.